产品描述
µ-Gard 气体变送器用于连续检测环境中的各种气体,广泛应用于各种环境,性能可靠,连接方便
应用
可适合各种商业应用,基于标准的4–20 mA 或 2-10 V模拟量输出,µ-Gard可配合各种控制器使用
特点
·连续检测 ·便于维护和校正
·内置电源保护电路 ·过载和短路保护
·长寿命传感器 ·低零点漂移
·有效防止中毒 ·4 – 20 mA 标准输出
·可选2 - 10 V 输出
技术参数
|
MA-0
CO
|
MA-9
O2
|
MA-9
NO
|
MA-2
NO2
|
MA-5
SO2
|
MA-2
NH3
|
MA-2
Ex
|
MA-2
NH3
|
MA-3
NH3
|
MA-4
Freon
|
MA-4
Ex
|
MA-3
ETO
|
传感器原理
|
电化学,扩散式
|
催化燃烧式
|
半导体
|
响应时间 t90 (s)
|
≤ 50
|
≤ 15
|
≤ 45
|
≤ 25
|
≤ 15
|
≤ 120
|
≤ 10 (甲烷)
|
≤ 100
|
≤ 50
|
≤ 30
|
≤ 50
|
分辨率
|
±3ppm
|
±0.1vol. %
|
±0.2 ppm
|
±0.2 ppm
|
0.2 ppm
|
<±20 ppm
|
± 1% of reading
|
---
|
---
|
---
|
---
|
重复性 (%)
|
± 3 %
|
---
|
---
|
± 2 %
|
± 2 %
|
---
|
---
|
---
|
---
|
---
|
---
|
零点漂移/年
|
< 5%
|
---
|
<0.3 ppm
|
<0.2 ppm
|
<0.2 ppm
|
---
|
±<6%LEL (Methane)
|
---
|
---
|
---
|
---
|
灵敏度漂移/月
|
---
|
< 4%/12
|
< 5%/12
|
< 2%/1
|
< 2%/1
|
< 2%/1
|
± < 1.5% Methane
|
---
|
---
|
---
|
---
|
传感器寿命 (正常使用环境)年
|
|
≥ 2
|
≥ 2
|
≥ 2
|
≥ 2
|
≥ 2
|
≥ 3
|
≥ 5
|
最长存贮时间
|
6 months
|
12 months
|
操作环境
|
湿度(无冷凝)
|
15 – 90 % RH
|
15 – 90 % RH
|
15 – 95 % RH
|
温度
|
工作温度
|
-10 to + 50°C
|
-30 to
+ 50 °C
|
-15 to + 50°C
|
-15 to + 50 °C
|
存贮温度
|
5 C to + 40 °C
|
0 to + 50 °C
|
0 to + 50 °C
|
工作压力
|
1大气压±10%
|
规格参数
供电 18 - 28 VDC
耗电量 电化学传感器: 22 mA, 0,6 VA
催化/半导体传感器: 35 mA, max. 0.85 VA
外壳(F) GW 塑料 75 GWT
阻燃性 UL 94: V0
外壳颜色 RAL 7032 (浅灰)
尺寸(d x H) 87 x 45,5 mm
重量 约 0.2 kg
防护等级 IP 43
安装方式 壁挂式
线缆 标准3线
线缆连接 0.25 mm2 (24 AWG)- 2.5 mm2 (14 AWG)
最大环路负载电阻500 Ω
输出信号
模拟输出信号
标准 4-20 mA 4 – 20 mA, ≤ 500 Ω带过载和短路保护
可选 2-10 V 2 – 10 V, ≥ 50 kΩ带过载和短路保护
执行标准 EMC 2004/108/EEC, CE
质保期 12个月(不含传感器)
|